PMWS & PCVD
![]() |
|
This free resource is kindly supported by:
If you have a information you would like is to include in this section please contact us
Vaccination
Management
Disease Information
A PMWS update (Jake Waddilove)
ABOUT PMWS & PDNS National Pork Board PMWS Fact Sheet About PDNS (Jake Waddilive) CEI Emerging Disease Notices: PMWS / PDNS Conference and meetings archive
Case Histories
Yorkshire Farm, UK - Mike Muirhead - Final Update, June 2002
Mike Muirhead's case history of a Yorkshire farm with PMWS and PDNS. This paper charts the course and effects of the disease on a single herd as well as highlighting the economic impact. Photographs
Clinical signs
Photos of the clinical signs that are seen generally in pigs with PMWS and PDNS. Includes skin lesions, enlarged lymph glands, wasting and dead pigs. Photos of the signs that are seen in post-mortem samples of pigs with PMWS and PDNS. Includes interstitial pneumonia, secondary bacterial infection, enlarged lymph nodes, oedema and intra cytoplasmic inclusions More Photos of the signs that are seen in post-mortem samples of pigs with PMWS and PDNS.
PMWS Research ArchivesPublished Wednesday, February 01, 2012: Journal of Virological Methods Volume 179, Issue 2, February 2012, Pages 311–315Development of a Plexor Real-Time PCR Assay for the Detection of Porcine Circovirus Type 2 Michaela Vlasakova, Anna Jackova, Valeria Leskova, Stefan Vilcek A novel, real-time PCR system for the detection of porcine circovirus type 2 (PCV2) was developed. The system employed Plexor technology and detected 108–101 copies per reaction of PCV2 DNA within a recombinant plasmid. The examination of clinical material showed consistent diagnostic sensitivity when samples contained more than 103 viral copies per reaction. Specificity of Plexor real-time PCR was confirmed using the porcine viruses PCV1, PRRSV, CSFV, TTSuV1 and TTSuV2 employing the melting curve analysis of PCR products. The low values of coefficient of variation in the intra- (1.74%) and inter-assay (2.41%) analysis suggested that the assay was a highly reproducible. The Plexor real-time PCR was compared with three other real-time PCR systems (SYBR Green, TaqMan, LUX) with conclusion that it can be used as a method of choice for the detection and quantitation of PCV2. To continue reading this article please click here Have you published information? To add please email the details |
Our Sponsors
Partners




















© 2000 - 2012. 5m Publishing, Benchmark House, 8 Smithy Wood Drive, Sheffield, S35 1QN, England.